Coriolis
Combines in-line viscosity and flow measurement with an ultra-compact transmitter.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
DN 8 to 80 (⅜ to 3")
Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
0 to 180 000 kg/h (0 to 6600 lb/min)
PN 100, Class 600, 63K
–50 to +150 °C (–58 to +302 °F)
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
1.4301/1.4307 (304L), corrosion resistant
Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Standard: IP66/67, type 4X enclosure
Option: IP69
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
None
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
DC 20 to 30 V
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
CE, C-Tick, EAC marking
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
PED, CRN
3.1 material
3-A, EHEDG, cGMP