Level radar
Water & Wastewater
(e.g. basins / channels / rivers / dams / lift stations /
storm water basins / pump control)
Utility applications in all industries
Storage tanks
Bluetooth® commissioning
Operation and maintenance SmartBlue App
Heartbeat Verification
2-wire (HART, 4…20 mA)
Bluetooth® wireless technology and App
(optional)
W-Band (~80 Ghz)
+/- 2mm (0.08")
-40…+80°C
(-40…+176°F)
-40…+80°C
(-40…+176°F)
-1…3 bar
(-14,5…43 psi)
PVDF, PBT/PC
Thread:
G1-1/2", NPT1-1/2"
Flange:
UNI flange 2“, 3“, 4“
UNI slip on flange 3“, 4“, 6“
30m (98.4 ft)
4...20 mA HART
Bluetooth® wireless technology
ATEX, C/US, EAC Ex, JPN Ex, KC Ex,
INMETRO Ex, NEPSI Ex, UK Ex
Overfill protection WHG
EU Food Contact Material (EC) 1935/2004
US Food Contact Material FDA CFR 21
ABS, LR, BV, DNV
NSF/ANSI 61
Display, Remote operation via SmartBlue App using
Bluetooth®
Remote HART indicator RIA15 in order
structure
Flooding protection tube
Different mounting possibilities
Process temp. <-40°C (-40°F) or > 80°C (176°F) -> FMR62B
Very aggressive media -> FMR62B
Turbulences, stilling well and bypass -> FMR62B
Strong foam and interfaces --> FMP5x