Thermal
The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement.
Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation.
Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.
DN 80 to 1500 (3 to 60")
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
Mass flow, temperature, corrected volume flow, FAD volume flow
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
20 bar g (290 psi g)
–40 to +100 °C (–40 to +212 °F)
–40 to +60 °C (–40 to +140 °F)
AlSi10Mg, coated
IP66/67, type 4X enclosure
4‐line display with push Buttons
Configuration via local display and operating tools possible
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Status input
HART
DC 18 to 30 V
ATEX, IECEx, cCSAus
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN