specifications | Details |
Product headline | High-temperature flowmeter for process applications as remote version with up to 4 I/Os. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
Sensor features | Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal Diameter | DN 15 - DN 600 (max. DN 600 / 24") |
Measuring Range | 4 dm³/min to 9600 m³/h (1 gal/min to 44,000 gal/min) |
Max. Measurement Error | Standard: ± 0.5 % o.r. ± 1 mm/s (0.04 in/s); Option: ± 0.2 % o.r. ± 2 mm/s (0.08 in/s) |
Liner Material | PFA: –20 to +150 °C (–4 to +302 °F); PFA High - temperature: –20 to +180 °C (–4 to +356 °F); PTFE: –40 to +130 °C (–40 to +266 °F) |
Electrodes | 1.4435 (316L); Alloy C22 (2.4602 / UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803) |
Max. Process Pressure | PN 40, Class 300, 20K |
Output | 4 - 20 mA HART (Active / Passive); 4 - 20 mA WirelessHART; 4 - 20 mA (Active / Passive); Pulse / Frequency / Switch Output (Active / Passive); Double Pulse Output (Active / Passive); Relay Output |
Input | Status Input, 4 - 20 mA Input |
Digital Communication | HART, Profibus DP, Profibus PA, Foundation Fieldbus, Modbus RS485, Profinet, Ethernet / IP, OPC - UA |
Power Supply | 24 VDC; 100 - 230 VAC |
Ambient Temperature Range (Flange Material Carbon Steel) | –10 to +60 °C (+14 to +140 °F) |
Protection Class | IP66/67, Type 4X |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |