KROHNE OPTIFLUX 2100 Electromagnetic flowmeter

OPTIFLUX 2100

Electromagnetic flowmeter for all standard water and wastewater applications

  • Chemically resistant liner materials
  • Compact version up to IP69, remote version IP68
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®


Electromagnetic flowmeter for water and wastewater applications 




Specifications

Depending on selected device configuration

General information

Product typeFlowmeter
Product family nameOPTIFLUX
Product positioningFor all standard water and wastewater applications
Measurement principleElectromagnetic
Measured mediaLiquids

Operating conditions

Process pressuremax. 40 barg/
580 psig
Process temperature-5…+90°C/
+23…+194°F

Materials

LinerPolypropylene (PP), Hard rubber

Process connections

Flange connectionsEN (1092-1): DN25…1200
ASME (B 16.5): 1…48"
JIS (B 2220): 25…1000A

Approvals/Standards

Certificates/Approvals ExATEX, IECEx, NEPSI, FM, CSA
Certificates/Approvals MarineABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Certificates/Approvals Potable WaterDVGW, NSF, TZW, KTW, WRAS, KIWA, ACS

Communication

Analogue outputs4…20 mA
Discrete outputsPulse, Frequency, Status
Digital outputsHART®

Videos

General

myDevice


OPTICHECK Service tools Powerful tools for instrument verification


Exchange of water meters with different lengths


KROHNE Water & Wastewater


Online planning tool for the creation of tender texts


PICK briefly explained - Access to the manufacturer’s digital documentation of your KROHNE devices


Tutorials

Filter

Filter

22 videos


GFC 300, IFC 100 | 300, MFC 300 | 400, UFC 300 F V2 | W V2 | 400


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

OPTIFLUX 2100


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

OPTIFLUX 2100


en

OPTIFLUX 2100


en

GFC 300, IFC 050 | 100 | 300 | 400, MFC 400, UFC 300 F V2 | W V2 | 400


en

Links


Electromagnetic flowmeters

Electromagnetic flowmeters

KROHNE Academy Online

This course deals with the principle of electromagnetic flow measurement, the construction of electromagnetic flowmeters and all relevant areas.

Accessories

OPTICHECK Master Verification tool
OPTICHECK Master

Handheld for in-depth verification, device commissioning and monitoring

  • On-site performance check and verification (level 0,1,2) without process interruption
  • Convenient commissioning of field devices, e.g. zero calibration
  • Detailed reports for proof test documentation of safety loops acc. to IEC 61508/61511, and for quality management systems (ISO 9001)
OPTICHECK DTM
OPTICHECK DTM

DTM for advanced device verification and commissioning

  • Usable with any FDT frame application from the control room or on site
  • Advanced verification (level 0,1) without process interruption
  • Detailed reports for proof test documentation of safety loops acc. to IEC 61508/61511, and for quality management systems (ISO 9001)

Applications

Heat and cold measurement in a data center
Heat and cold measurement in a data center

Application Note | Data Center

  • Measurement of energy flows for cooling and heating purposes
  • Complete instrumentation package to guarantee availability and sustainability
  • Coverage of various heat transfer fluids
  • Custody transfer heat flow measurement to feed the district heating grid
Flow and level measurement on a liquid manure spreader
Flow and level measurement on a liquid manure spreader

Application Report | Agriculture

  • Effective nutrient management of liquid slurry in line with environmental regulations
  • Process instrumentation for even distribution of fertilizer
  • Prevention of nutrient loss and fertilizer run-off
Dosing of sodium hypochlorite solution for drinking water disinfection
Dosing of sodium hypochlorite solution for drinking water disinfection

Application Note | Water & Wastewater

  • Increased process safety and reduced consumption of liquid bleach in the chlorination plant of a water purveyor
  • Reliable and long-term stable flow measurement of an aggressive liquid by using an electromagnetic flowmeter with ceramic measuring tube
  • Additional flow instrumentation for the pumping station from one source
  • Reduced service costs: Performance verification of all flowmeters with one single service tool
Equipping a cheese dairy with flow, level and analysis instruments
Equipping a cheese dairy with flow, level and analysis instruments

Application Report | Food & Beverage

  • Automation of a production site for premium cheese
  • Providing information on various plant operations – from raw milk reception to cheese preparation to sterilisation and wastewater management
  • Cross-company and cross-country project management to fulfil customer requirements on time
Portable flow measurement of wine and juice
Portable flow measurement of wine and juice

Application Report | Food & Beverage

  • Electromagnetic flow metering to automate transfer operations
  • Monitoring the quantity of juice and wine moved from one tank to another
  • Highly flexible solution for temporary flow measurement and pump control
Detecting the leakage of coolant in a blast furnace
Detecting the leakage of coolant in a blast furnace

Application Report | Metal & Mining

  • Protection of furnace lining and shell through internal cooling system
  • Electromagnetic flow measurement of chemically purified water
  • Advanced leakage monitoring system with over 530 flowmeters

Downloads

Filter

Filter




Title
Document Type

Handbooks
IFC 100
Handbooks






























































































































Handbooks
OPTIFLUX 2000
Handbooks






























































































































Quick Starts
IFC 100
Handbooks

























































































































































Quick Starts
OPTIFLUX 2000
Handbooks





























































































































































































Supplementary instructions Ex / Hazardous Areas
OPTIFLUX 2000 | 2100 | 4100 | 6100
IFC 100, ATEX, IECEx, EPL Gb Zone 1, EPL Db Zone 21, Ex e, Ex i or IS, Ex m, Ex q, Ex t or DIP, FTZU13ATEX0175X, FTZU150010X, FTZU15ATEX0036X, FTZU15ATEX0037X, IECExFTZU140001X, IECExFTZU150012X, IECExKIWA170016X, KIWA17ATEX0033 X
Handbooks












Supplementary instructions Ex / Hazardous Areas
OPTIFLUX 2000 | 2400 | 4000 | 4400
IFC 400, ATEX, IECEx, EPL Gb Zone 1, EPL Db Zone 21, Ex d or XP, Ex e, Ex i or IS, Ex m, Ex q, Ex t or DIP, FTZU13ATEX0175X, IECExFTZU140001X
Handbooks
































Supplementary instructions Ex / Hazardous Areas
OPTIFLUX 2100 | 4000 | 4100
IFC 100, IECEx, EPL Gb Zone 1, EPL Db Zone 21, Ex d or XP, Ex i or IS, Ex m, Ex t or DIP, IECExKEM090073X
Handbooks










Supplementary instructions Ex / Hazardous Areas
OPTIFLUX 2100 | 4100
IFC 100, Brazil Ex | INMETRO, EPL Gb Zone 1, EPL Db Zone 21, Ex d or XP, Ex i or IS, Ex m, Ex q, Ex t or DIP, DNV120038X, DNV120040X
Handbooks








Supplementary instructions Ex / Hazardous Areas
OPTIFLUX 2100 | 4100 | 5000 | 5100 | 6100
IFC 100, ATEX, EPL Gb Zone 1, EPL Db Zone 21, Ex d or XP, Ex i or IS, Ex m, Ex q, Ex t or DIP, KEMA04ATEX2125X, KEMA04ATEX2126X, KEMA07ATEX0020X, KEMA07ATEX0199X, KEMA08ATEX0157X
Handbooks














Supplementary instructions Communication
IFC 100
Modbus
Handbooks






Supplementary instructions Communication
IFC 100
FF
Handbooks






Supplementary instructions Communication
IFC 100
PROFIBUS DP, PROFIBUS
Handbooks









Technical Data Sheets
IFC 100
Datasheets








































































































Technical Data Sheets
OPTIFLUX 2000
Datasheets












































































































Ex certificates
ENVIROMAG 2000 | 2100
IFC 100
OPTIFLUX 1000 | 1100 | 2000 | 2100 | 4000 | 4100 | 5000 | 5100 | 6000 | 6100
Ordinary Location Canada, Ordinary Location US, -, CSA
Certificates












Ex certificates
ENVIROMAG 2000
IFC 300
OPTIFLUX 1000 | 1300 | 2000 | 2300 | 4000 | 4300 | 5000 | 5300 | 6000 | 6300
Ordinary Location Canada, Ordinary Location US, -, CSA
Certificates







Showing 16 of 129


Overview

The OPTIFLUX 2100 is an electromagnetic flowmeter (EMF) for standard water and wastewater applications. It is the ideal solution for all general flow applications where reliable flow measurement with sufficient yet not extremely high accuracy is required. Installation in measurement chambers subject to (constant) flooding is possible with the remote IP68 / NEMA 6P rated version.

Features & Options

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.


  • Bi-directional flow measurement over a wide dynamic range
  • Optional for subsoil installation and constant flooding
  • Proven and unsurpassed life time, huge installed base
  • Standard wet calibration
  • PP or hard rubber liner: suitable for low concentrated chemicals
  • Tamper proof
  • Standard measurement accuracy: ±0.3% or ±1mm/s of measured value (MV)
  • Diagnostics incl. conductivity, electrode error, ambient and process temperature etc.
  • Full bore design: No moving parts, no wear, no pressure loss
  • Meets potable water standards: ACS, DVGW, NSF, TZW, WRAS etc.


  • For hazardous areas: ATEX, IECEx, FM, CSA


  • On-site verification of flowmeter with OPTICHECK service tool