Krohne OPTIFLUX 4100 Electromagnetic flowmeter

OPTIFLUX 4100

Electromagnetic flowmeter for standard applications with abrasive and aggressive liquids

  • Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…1200 / ⅒…48", max. PN40 / ASME Cl 600
  • 4…20 mA, pulse, frequency, status, HART®


OPTIFLUX 4100 C Electromagnetic flowmeter – Compact version

Specifications

Depending on selected device configuration

General information

Product typeFlowmeter
Product family nameOPTIFLUX
Product positioningFor standard applications with abrasive and aggressive liquids
Measurement principleElectromagnetic
Measured mediaLiquids

Operating conditions

Process pressuremax. 40 barg/
580 psig
Process temperature-40…+180°C/
-40…+356°F

Materials

LinerPerfluoroalkoxy alkane (PFA), Polytetrafluoroethylene (PTFE), Polyuretane (PUR), Hard rubber, Ethylene tetrafluoroethylene (ETFE), Soft rubber

Process connections

Flange connectionsEN (1092-1): DN2.5…1200
ASME (B 16.5): ⅒…48"
JIS (B 2220): 2.5…1000A

Approvals/Standards

Certificates/Approvals ExATEX, IECEx, NEPSI, FM, CSA
Certificates/Approvals HygienicFDA
Certificates/Approvals MarineABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS

Communication

Analogue outputs4…20 mA
Discrete outputsPulse, Frequency, Status
Digital outputsHART®

Overview

The OPTIFLUX 4100 is an electromagnetic flowmeter (EMF) for a wide range of standard process applications with aggressive and abrasive liquids. It enables reliable flow measurement even under harsh process conditions with temperatures up to +180°C / +356°F, low conductivity (≥5 µS/cm) and solid content (up to 10%). This makes the flowmeter particularly suitable for applications involving corrosive chemicals, sewage and drilling mud or mining sludge. Installation in measurement chambers subject to (constant) flooding is also possible using the optional IP68 / NEMA 6P rated version.

Features & Options

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.


  • Bi-directional flow measurement over a wide dynamic range (turndown ratio: 1000:1)
  • PTFE, PFA, ETFE, hard rubber, soft rubber or PU liner: excellent chemical and abrasion resistance
  • Wide range of electrode materials
  • Special designs, sizes, inner diameters and liner thicknesses on request
  • Standard measurement accuracy: ±0.3% or ±1mm/s of measured value (MV)
  • Optional external coatings for offshore or subsoil installation (also acc. to ISO 12944)
  • Diagnostics incl. conductivity, electrode error, ambient and process temperature etc.
  • Full bore design: No moving parts, no wear, no pressure loss
  • For hazardous areas: ATEX, IECEx, FM, CSA
  • On-site verification of flowmeter with OPTICHECK service tool