Rosemont 8600D Vortex Flowmeter Flow Meter
Product Description
Emerson Rosemount 8600 Series Utility Vortex Flowmeter Flow Meter for Gas, Liquid

Rosemount™ 8600 Vortex Flow Meters

The Rosemount 8600 Vortex flow meter is optimized for general purpose flow metering and utility applications including clean fluids and steam flow. The 8600 Vortex meter offers enhanced reliability and simplified maintenance with superior vibration immunity without any moving parts. Installation is easy with no impulse lines or zeroing required and internal verification of both the electronics and sensor add enhanced process insight.

 

Features

 
  • Ensure reliability and cut costs with no moving parts to repair or maintain
  • Eliminate impulse lines and plugging issues with inline technology
  • Simplify installation with no impulse lines or field calibration or zeroing required
  • Cover a broad span of flow rates with wide rangeability
  • Electronics verification enables simplified troubleshooting
  • Perform easy maintenance with replaceable sensors
  • Remote mount electronics offered for easy access
Emerson Rosemount 8600 Series Utility Vortex Flowmeter Flow Meter for Gas, Liquid
Emerson Rosemount 8600 Series Utility Vortex Flowmeter Flow Meter for Gas, Liquid

Intelligent Vortex Flow Meter--Rosemount 8600 Utility Vortex Flowmeter

Intelligent Vortex Flow Meter Rosemount 8600 Utility Vortex Flowmeter Delivering on a foundation of measurement technology, Rosemount Vortex Flowmeters have a wide range of options to fit a variety of process and utility applications. The Rosemount 8600 Utility™ Vortex Flowmeter improves...

The Rosemount 8600 Utility™ Vortex Flowmeter improves reliability and reduces installed cost by minimizing potential leak points and eliminating the need for impulse lines.
•    Reduce installed costs
•    Ease of installation
•    Greater reliability
•    Excellent rangeability

The Rosemount 8600 Utility Flowmeters are suitable for liquid, gas, and steam applications. The high

performance of the Rosemount 8600 Flowmeters solve your utility flow applications needs by:

 

•    Eliminating clogging and reducing potential leak points associated with impulse lines

•    Using a mass balanced sensor and Adaptive Digital Signal Processing to provide vibration immunity

•    Decreases Energy and Utility Costs with Rosemount Vortex Flowmeters

Emerson Rosemount 8600 Series Utility Vortex Flowmeter Flow Meter for Gas, Liquid

The Rosemount 8600D Vortex Flowmeter consists of a meter body and transmitter and measures volumetric flow rate by detecting the vortices created by a fluid passing by the shedder bar. The meter body is installed in-line with process piping. A sensor is located at the end of the shredder bar and creates an alternating sine wave due to the passing vortices. The transmitter measures the frequency of the sine waves and converts it into a flowrate. This manual is designed to assist in the installation and operation of the Rosemount 8600D Vortex Flowmeter
Rosemount 8600 MultiVariable™ Vortex reduces installation costs, simplifies installation, and improves performance in saturated steam

  • Flow Meter Accuracy± 0.75% of volumetric rate for liquids.± 1% of volumetric rate for gas and steam.± 2% of rate for mass flow on steam using 8600 MultiVariable (MTA option).
  • Turndown30:1
  • Output4-20 mA with HART 5 or 7. 4-20 mA with HART 5 or 7 and scalable pulse output.
  • Wetted MaterialStainless Steel - CF3M & CF8M.
  • Flange OptionsANSI Class 150 and 300.DIN PN 10 and PN 40
  • Process Temperature Limits-58°F to 482°F (-50°C to 250°C)
  • Temperature Sensor Range Using 8600 MultiVariable (MTA option): -40 to 800°F (-40 to 427°C)
  • Line Size: 1 to 8-in; 25 to 200 mm
Emerson Rosemount 8600 Series Utility Vortex Flowmeter Flow Meter for Gas, Liquid
Emerson Rosemount 8600 Series Utility Vortex Flowmeter Flow Meter for Gas, Liquid

 

Product Parameters

Specification

Key Specifications

Accuracy

± 0.75% of rate for liquids;

± 1% of rate for gas and steam

Turndown

30:1

Output 

4-20 mA with HART®

4-20 mA with HART® and Scalable Pulse Output

Wetted Material

Stainless Steel - CF3M

Flange Options

ANSI Class 150 to 300;

DIN PN 10 to PN 40

Operating   Temperatures

-58°F to 482°F (-50°C to 250°C)

Line Size

Flanged - 1-in to 8-in (25 to 200 mm)